1. Introduction
Increasingly, sensor data is used in application development to enable new use cases such as geolocation, counting steps or head-tracking. This is especially true on mobile devices where new sensors are added regularly.
Exposing sensor data to the Web has so far been both slow-paced and ad-hoc. Few sensors are already exposed to the Web. When they are, it is often in ways that limit their possible use cases (for example by exposing abstractions that are too high-level and which don’t perform well enough). APIs also vary greatly from one sensor to the next which increases the cognitive burden of Web application developers and slows development.
The goal of the Generic Sensor API is to promote consistency across sensor APIs, enable advanced use cases thanks to performant low-level APIs, and increase the pace at which new sensors can be exposed to the Web by simplifying the specification and implementation processes.
A comprehensive list of concrete sensors that are based on Generic Sensor API, applicable use cases, and code examples can be found in [GENERIC-SENSOR-USECASES] and [MOTION-SENSORS] explainer documents.
2. Scope
This section is non-normative.
The scope of this specification is currently limited to specifying primitives which enable exposing data from device sensors.
Exposing remote sensors or sensors found on personal area networks (e.g. Bluetooth) is out of scope. As work in these areas mature, it is possible that common, lower-level primitives be found, in which case this specification will be updated accordingly. This should have little to no effects on implementations, however.
This specification also does not currently expose a sensor discovery API. This is because the limited number of sensors currently available to user agents does not warrant such an API. Using feature detection, such as described in § 3 A note on Feature Detection of Hardware Features, is good enough for now. A subsequent version of this specification might specify such an API, and the current API has been designed with this in mind.
3. A note on Feature Detection of Hardware Features
This section is non-normative.
Feature detection is an established Web development best practice. Resources on the topic are plentiful on and offline and the purpose of this section is not to discuss it further, but rather to put it in the context of detecting hardware-dependent features.
Consider the below feature detection examples:
if ( typeof Gyroscope=== "function" ) { // run in circles... } if ( "ProximitySensor" in window) { // watch out! } if ( window. AmbientLightSensor) { // go dark... } // etc.
All of these tell you something about the presence and possible characteristics of an API. They do not tell you anything, however, about whether that API is actually connected to a real hardware sensor, whether that sensor works, if its still connected, or even whether the user is going to allow you to access it. Note you can check the latter using the Permissions API [PERMISSIONS].
In an ideal world, information about the underlying status would be available upfront. The problem with this is twofold. First, getting this information out of the hardware is costly, in both performance and battery time, and would sit in the critical path. Secondly, the status of the underlying hardware can evolve over time. The user can revoke permission, the connection to the sensor be severed, the operating system may decide to limit sensor usage below a certain battery threshold, etc.
Therefore, an effective strategy is to combine feature detection, which checks whether an API for the sought-after sensor actually exists, and defensive programming which includes:
-
checking for error thrown when instantiating a
Sensor
object, -
listening to errors emitted by it,
-
handling all of the above graciously so that the user’s experience is enhanced by the possible usage of a sensor, not degraded by its absence.
let accelerometer= null ; try { accelerometer= new Accelerometer({ frequency: 10 }); accelerometer. addEventListener( 'error' , event=> { // Handle runtime errors. if ( event. error. name=== 'NotAllowedError' ) { console. log( 'Permission to access sensor was denied.' ); } else if ( event. error. name=== 'NotReadableError' ) { console. log( 'Cannot connect to the sensor.' ); } }); accelerometer. addEventListener( 'reading' , () => reloadOnShake( accelerometer)); accelerometer. start(); } catch ( error) { // Handle construction errors. if ( error. name=== 'SecurityError' ) { console. log( 'Sensor construction was blocked by the Feature Policy.' ); } else if ( error. name=== 'ReferenceError' ) { console. log( 'Sensor is not supported by the User Agent.' ); } else { throw error; } }
4. Security and privacy considerations
Sensor readings are sensitive data and could become a subject of various attacks from malicious Web pages. Before discussing the mitigation strategies we briefly enumerate the main types of the sensor's privacy and security threats. The [MOBILESENSORS] categorizes main threats into location tracking, eavesdropping, keystroke monitoring, device fingerprinting, and user identification. This categorization is a good fit for this specification.
The risk of successful attack can increase when sensors are used with each other, in combination with other functionality, or when used over time, specifically with the risk of correlation of data and user identification through fingerprinting. Web application developers using these JavaScript APIs should consider how this information might be correlated with other information and the privacy risks that might be created. The potential risks of collection of such data over a longer period of time should also be considered.
Variations in sensor readings as well as event firing rates offer the possibility of fingerprinting to identify users. User agents may reduce the risk by limiting event rates available to web application developers.
Minimizing the accuracy of a sensor’s readout generally decreases the risk of fingerprinting. User agents should not provide unnecessarily verbose readouts of sensors data. Each sensor type should be assessed individually.
If the same JavaScript code using the API can be used simultaneously in different window contexts on the same device it may be possible for that code to correlate the user across those two contexts, creating unanticipated tracking mechanisms.
User agents should consider providing the user an indication of when the sensor is used and allowing the user to disable it. Additionally, user agents may consider allowing the user to verify past and current sensor use patterns.
Web application developers that use sensors should perform a privacy impact assessment of their application taking all aspects of their application into consideration.
Ability to detect a full working set of sensors on a device can form an identifier and could be used for fingerprinting.
A combination of selected sensors can potentially be used to form an out of band communication channel between devices.
Sensors can potentially be used in cross-device linking and tracking of a user.
4.1. Types of privacy and security threats
This section is non-normative.
4.1.1. Location Tracking
Under this type of threat, the attacks use sensor readings to locate the device without using GPS or any other location sensors. For example, accelerometer data can be used to infer the location of smartphones by using statistical models to obtain estimated trajectory, then map matching algorithms can be used to obtain predicted location points (within a 200-m radius)[MOBILESENSORS].
4.1.2. Eavesdropping
Recovering speech from gyroscope readings is an example of eavesdropping attack. See [GYROSPEECHRECOGNITION].
4.1.3. Keystroke Monitoring
Many user inputs can be inferred from sensor readings, this includes a wide range of attacks on user PINs, passwords, and lock patterns (and even touch actions such as click, scroll, and zoom) using motion sensors. These attacks normally train a machine learning algorithm to discover such information about the users. See [STEALINGPINSVIASENSORS].
4.1.4. Device Fingerprinting
Sensors can provide information that can uniquely identify the device using those sensors. Every concrete sensor model has minor manufacturing imperfections and differences that will be unique for this model. These manufacturing variations and imperfections can be used to fingerprint the device [ACCELPRINT] [MOBILESENSORS].
4.1.5. User Identifying
Sensor readings can be used to identify the user, for example via inferring individual walking patterns from smartphone or wearable device motion sensors' data.
4.2. Mitigation Strategies
This section is non-normative.
This section gives a high-level presentation of some of the mitigation strategies specified in the normative sections of this specification.
4.2.1. Secure Context
Sensor readings are explicitly flagged by the Secure Contexts specification [POWERFUL-FEATURES] as a high-value target for network attackers. Thus all interfaces defined by this specification or extension specifications are only available within a secure context.
4.2.2. Feature Policy
To avoid the privacy risk of sharing sensor readings with contexts unfamiliar to the user, sensor readings are only available for the documents which are allowed to use the policy-controlled features for the given sensor type. See [FEATURE-POLICY] for more details.
4.2.3. Focused Area
Sensor readings are only available for active documents whose origin is same origin-domain with the currently focused area document.
This is done in order to mitigate the risk of a skimming attack against the browsing context containing an element which has gained focus, for example when the user carries out an in-game purchase using a third party payment service from within an iframe.
4.2.4. Visibility State
Sensor readings are only available for the active documents whose visibility state is "visible".
4.2.5. Permissions API
Access to sensor readings are controlled by the Permissions API [PERMISSIONS].
4.3. Mitigation strategies applied on a case by case basis
Each sensor type will need to be assessed individually, taking into account the use cases it enables and its particular threat profile. While some of the below mitigation strategies are effective for certain sensors, they might also hinder or altogether prevent certain use cases.
Note: These mitigation strategies can be applied constantly or temporarily, for example when the user is carrying out specific actions, when other APIs which are known to amplify the level of the threat are in use, etc.
4.3.1. Limit maximum sampling frequency
User agents may mitigate certain threats by limiting the maximum sampling frequency. What upper limit to choose depends on the sensor type, the kind of threats the user agent is trying to protect against, the expected resources of the attacker, etc.
Limiting the maximum sampling frequency prevents use cases which rely on low latency or high data density.
4.3.2. Stop the sensor altogether
This is obviously a last-resort solution, but it can be extremely effective if it’s temporal, for example to prevent password skimming attempts when the user is entering credentials on a different origin ([rfc6454]) or in a different application.
4.3.3. Limit number of delivered readings
An alternative to limiting the maximum sampling frequency is to limit the number of sensor readings delivered to Web application developer, regardless of what frequency the sensor is polled at. This allows use cases which have low latency requirement to increase sampling frequency without increasing the amount of data provided.
Discarding intermediary readings prevents certain use cases, such as those relying on certain kinds of filters.
4.3.4. Reduce accuracy
Reducing the accuracy of sensor readings or sensor reading timestamps might also help mitigate certain threats, thus user agents should not provide unnecessarily verbose readouts of sensors data.
Note: Inaccuracies will further increase for operations carried out on the sensor readings, or time deltas calculated from the timestamps. So, this mitigation strategy can affect certain use cases.
Note: while adding random bias to sensor readings has similar effects, it shouldn’t be used in practice as it is easy to filter out the added noise.
4.3.5. Keep the user informed about API use
User agents may choose to keep the user informed about current and past use of the API.
Note: this does not imply keeping a log of the actual sensor readings which would have issues of its own.
5. Concepts
5.1. Sensors
The term device sensor refers to a device’s underlying physical sensor instance.
A device sensor measures a physical quantities and provides a corresponding sensor reading which is a source of information about the environment.
Each sensor reading is composed of the values of the physical quantity measured by the device sensor at time tn which is called the reading timestamp.
If the device sensor performs a spatial measurement (e.g. acceleration, angular velocity), it must be resolved in a local coordinate system that represents a reference frame for the device sensor's sensor readings. A device sensor that provides such sensor readings is referred to as spatial sensor.
A spatial sensor can be uniaxial, biaxial, or triaxial, depending on the number of orthogonal axes in which it can perform simultaneous measurements.
Scalar physical quantities (i.e. temperature) do not require a local coordinate system for resolution.
The local coordinate system normally used in a mobile device is a Cartesian coordinate system, which is defined relative to the device’s screen, so that X and Y axes are parallel to the screen dimentions and Z axis is perpendicular to the screen surface.
The term platform sensor refers to platform interfaces, with which the user agent interacts to obtain sensor readings for a single sensor type originated from one or more device sensors.
Platform sensor can be defined by the underlying platform (e.g. in a native sensors framework) or by the user agent, if it has a direct access to device sensor.
From the implementation perspective platform sensor can be treated as a software proxy for the corresponding device sensor. It is possible to have multiple platform sensors simultaneously interacting with the same device sensor if the underlying platform suppports it.
In simple cases, a platform sensor corresponds to a single device sensor, but if the provided sensor readings are a product of sensor fusion performed in software, the platform sensor corresponds to a set of device sensors involved in the sensor fusion process.
Discrepancies between a sensor reading and the corresponding physical quantity being measured are corrected through calibration that can happen at manufacturing time. Some sensors can require dynamic calibration to compensate unknown discrepancies.
Note: platform sensors created through sensor fusion are sometimes called virtual or synthetic sensors. However, the specification doesn’t make any practical distinction between them.
5.2. Sensor Types
Different sensor types measure different physical quantities such as temperature, air pressure, heart-rate, or luminosity.
For the purpose of this specification we distinguish between high-level and low-level sensor types.
Sensor types which are characterized by their implementation are referred to as low-level sensors. For example a Gyroscope is a low-level sensor type.
Sensors named after their readings,
regardless of the implementation,
are said to be high-level sensors.
For instance, geolocation sensors provide information about the user’s location,
but the precise means by which this data is obtained
is purposefully left opaque
(it could come from a GPS chip, network cell triangulation,
wifi networks, etc. or any combination of the above)
and depends on various, implementation-specific heuristics. High-level sensors are generally the fruits of
applying algorithms to low-level sensors—
That said, the distinction between high-level and low-level sensor types is somewhat arbitrary and the line between the two is often blurred.
For instance, a barometer, which measures air pressure,
would be considered low-level for most common purposes,
even though it is the product of the sensor fusion of
resistive piezo-electric pressure and temperature sensors.
Exposing the sensors that compose it would serve no practical purpose;
who cares about the temperature of a piezo-electric sensor?
A pressure-altimeter would probably fall in the same category,
while a nondescript altimeter—
Because the distinction is somewhat blurry, extensions to this specification (see § 10 Extensibility) are encouraged to provide domain-specific definitions of high-level and low-level sensors for the given sensor types they are targeting.
Sensor readings from different sensor types can be combined together through a process called sensor fusion. This process provides higher-level or more accurate data (often at the cost of increased latency). For example, the readings of a triaxial magnetometer needs to be combined with the readings of an accelerometer to provide a correct bearing.
Smart sensors and sensor hubs have built-in compute resources which allow them to carry out calibration and sensor fusion at the hardware level, freeing up CPU resources and lowering battery consumption in the process.
Sensor fusion can also be carried out in software if it cannot be performed at the hardware level or if an application-specific fusion algorithm is required.
5.3. Default sensor
The Generic Sensor API is designed to make the most common use cases straightforward while still enabling more complex use cases.
Most of devices deployed today do not carry more than one device sensor providing sensor readings of the same type. The use cases which require a set of similar device sensors are rare and generally limited to specific sensor types, such as multiple accelerometers in 2-in-1 laptops.
The API therefore makes it easy to interact with
the device’s default (and often unique) sensor for each type simply by instantiating the corresponding Sensor
subclass.
Indeed, without specific information identifying a particular sensor of a given type, the default sensor is chosen by the user agent.
If the underlying platform provides an interface to find the default sensor, the user agent must choose the sensor offered by the platform, otherwise the user agent itself defines which of the sensors present on the device is the default sensor.
let sensor= new Accelerometer({ frequency: 30 }); sensor. onreading= () => { ... } sensor. start();
Note: extension to this specification may choose not to define a default sensor when doing so wouldn’t make sense. For example, it does not make sense to explicitly define a default sensor for geolocation sensor type as the implementation of its interface can use multiple backends.
In cases where multiple device sensors corresponding to the same type may coexist on the same device, specification extension will have to define ways to uniquely identify each one.
var sensor= new DirectTirePressureSensor({ position: "rear" , side: "left" }); sensor. onreading= _=> console. log( sensor. pressure); sensor. start();
5.4. Reading change threshold
A platform sensor reports readings to the user agent considering the reading change threshold.
The reading change threshold refers to a value which indicates whether or not the changes in the device sensor's measurements were significant enough to update the corresponding sensor readings.
The threshold value depends on the surrounding software and hardware environment constraints, e.g., software power consumption optimizations or the underlying device sensor's accuracy.
5.5. Sampling Frequency and Reporting Frequency
For the purpose of this specification, sampling frequency for a platform sensor is defined as a frequency at which the user agent obtains sensor readings from the underlying platform.
The user agent can request the underlying platform to deliver readings at a certain rate which is called requested sampling frequency.
The sampling frequency is equal to the requested sampling frequency if the underlying platform can support it.
The sampling frequency differs from the requested sampling frequency in the following cases:
-
the requested sampling frequency exceeds upper or lower sampling frequency bounds supported by the underlying platform.
-
the threshold value is significant so that some of the device sensor's measurements are skipped and the sensor readings are not updated.
The reporting frequency for a concrete Sensor
object is defined as a frequency at which
the "reading" event is fired at this object.
A Sensor
object cannot access new readings at a higher rate than the
user agent obtains them from the underlying platform, therefore the reporting frequency can
never exceed the sampling frequency for the given sensor type.
5.6. Conditions to expose sensor readings
The user agent must verify that all mandatory conditions are satisfied to ensure it can expose sensor readings to the Sensor
objects of a certain type that belong to a certain active document.
The mandatory conditions are the following:
-
The given document is a responsible document of a secure context.
-
For each permission name from the sensor type's associated sensor permission names set, the corresponding permission’s state is "granted".
-
Visibility state of the document is "visible".
-
The document is allowed to use all the policy-controlled features associated with the given sensor type.
-
Currently focused area belongs to a document whose origin is same origin-domain with the origin of the given active document.
-
Specific conditions: The extension specifications that add new conditions hook into this specification at this point.
Note: In order to release hardware resources, the user agent can request underlying platform sensor to suspend notifications about newly available readings until it can expose sensor readings.
6. Model
6.1. Sensor Type
A sensor type has one or more associated extension sensor interfaces.
A sensor type has a set of associated sensors.
A sensor type may have a default sensor.
A sensor type has a nonempty set of associated permission names referred to as sensor permission names.
Note: multiple sensor types may share the same permission name.
A sensor type has a permission revocation algorithm.
To invoke the permission revocation algorithm with PermissionName
permission_name, run the following steps:
-
For each sensor_type whose permission names contains permission_name:
-
For each sensor in sensor_type’s set of associated sensors,
-
Invoke revoke sensor permission with sensor as argument.
-
-
A sensor type has a permission request algorithm.
A sensor type has a nonempty set of associated policy-controlled feature tokens referred to as sensor feature names.
6.2. Sensor
The current browsing context's platform sensor has an associated set of activated sensor objects, which is initially empty and an associated latest reading map, which holds the latest available sensor readings.
Note: User agents can share the latest reading map and the activated sensor objects set between different contexts only if the origins of these contexts' active documents are same origin-domain.
Any time a new sensor reading for a platform sensor is obtained and if the user agent can expose sensor readings to the current browsing context's active document, the user agent invokes update latest reading with the platform sensor and the sensor reading as arguments.
The latest reading map contains an entry whose key is "timestamp" and whose value is a high resolution timestamp that estimates the reading timestamp expressed in milliseconds since the time origin.
Note: The accuracy of the reading timestamp estimate depends on the underlying platform interfaces that expose it.
The latest reading["timestamp"] is initially set to null, unless the latest reading map caches a previous reading.
The other entries of the latest reading map hold the values of the different quantities measured by the platform sensor. The keys of these entries must match the attribute identifier defined by the sensor type's associated extension sensor interface. The return value of the attribute getter is easily obtained by invoking get value from latest reading with the object implementing the extension sensor interface and the attribute identifier as arguments.
The value of all latest reading entries is initially set to null.
A platform sensor has an associated requested sampling frequency which is initially null.
For a nonempty set of activated sensor objects the requested sampling frequency is equal to optimal sampling frequency, which is estimated
by the user agent taking into account provided frequencies
of activated Sensors
and sampling frequency bounds
defined by the underlying platform.
Note: For example, the user agent may estimate optimal sampling frequency as a Least Common
Denominator (LCD) for a set of provided frequencies
capped
by sampling frequency bounds defined by the underlying platform.
This example illustrates a possible implementation of the described Model.
In the diagram below several activated Sensor
objects from two
different browsing contexts interact with a single device sensor.
The Sensor
object in "idle" state is not among the platform sensor's activated sensor objects and thus it does not interact with the device sensor.
In this example there is a platform sensor instance per browsing context.
The latest reading map is shared between Sensor
objects from the
same context and is updated at rate equal to requested sampling frequency of the corresponding platform sensor.
7. API
7.1. The Sensor Interface
[SecureContext ,Exposed =(DedicatedWorker ,Window )]interface :
Sensor EventTarget {readonly attribute boolean ;
activated readonly attribute boolean ;
hasReading readonly attribute DOMHighResTimeStamp ?;
timestamp void ();
start void ();
stop attribute EventHandler ;
onreading attribute EventHandler ;
onactivate attribute EventHandler ; };
onerror dictionary {
SensorOptions double ; };
frequency
A Sensor
object has an associated platform sensor.
The task source for the tasks mentioned in this specification is the sensor task source.
The event handler event types for the corresponding Sensor Interface's event handler attributes are defined in Event handlers section.
navigator. permissions. query({ name: 'accelerometer' }). then( result=> { if ( result. state=== 'denied' ) { console. log( 'Permission to use accelerometer sensor is denied.' ); return ; } let acl= new Accelerometer({ frequency: 30 }); let max_magnitude= 0 ; acl. addEventListener( 'activate' , () => console. log( 'Ready to measure.' )); acl. addEventListener( 'error' , error=> console. log( `Error: ${ error. name} ` )); acl. addEventListener( 'reading' , () => { let magnitude= Math. hypot( acl. x, acl. y, acl. z); if ( magnitude> max_magnitude) { max_magnitude= magnitude; console. log( `Max magnitude: ${ max_magnitude} m/s2` ); } }); acl. start(); });
7.1.1. Sensor lifecycle
Note: the nodes in the diagram above represent the states of a Sensor
object and they should not be
confused with the possible states of the underlying platform sensor or device sensor.
7.1.2. Sensor garbage collection
A Sensor
object whose [[state]]
is "activating" must not be garbage collected
if there are any event listeners registered for "activated" events, "reading" events,
or "error" events.
A Sensor
object whose [[state]]
is "activated" must not be garbage collected
if there are any event listeners registered for "reading" events, or "error" events.
When a Sensor
object whose [[state]]
is "activated" or "activating" is
garbage collected, the user agent must invoke deactivate a sensor object with this object as argument.
7.1.3. Sensor internal slots
Instances of Sensor
are created
with the internal slots described in the following table:
Internal Slot | Description (non-normative) |
---|---|
[[state]]
| The current state of the Sensor object which is one of
"idle",
"activating", or
"activated".
It is initially "idle".
|
[[frequency]]
|
A double representing frequency in Hz that is used to calculate
the requested sampling frequency for the associated platform sensor and to define the upper bound of the reporting frequency for this Sensor object.
This slot holds the provided |
[[lastEventFiredAt]]
| The high resolution timestamp of the latest sensor reading that was sent to observers of the Sensor object,
expressed in milliseconds that passed since the time origin.
It is initially null.
|
[[pendingReadingNotification]]
| A boolean which indicates whether the observers need to be notified after a new sensor reading was reported. It is initially false. |
7.1.4. Sensor.activated
The getter of the activated
attribute must run these steps:
-
If this.
[[state]]
is "activated", return true. -
Otherwise, return false.
7.1.5. Sensor.hasReading
The getter of the hasReading
attribute must run these steps:
-
Let timestamp be the result of invoking get value from latest reading with this and "timestamp" as arguments.
-
If timestamp is not null, return true.
-
Otherwise, return false.
7.1.6. Sensor.timestamp
The getter of the timestamp
attribute returns
the result of invoking get value from latest reading with this and "timestamp" as arguments. It represents a reading timestamp.
7.1.7. Sensor.start()
The start()
method must run these steps:
-
Let sensor_state be the value of sensor_instance.
[[state]]
. -
If sensor_state is either "activating" or "activated", then return.
-
Set sensor_instance.
[[state]]
to "activating". -
Run these sub-steps in parallel:
-
let connected be the result of invoking connect to sensor with sensor_instance as argument.
-
If connected is false, then
-
Let e be the result of creating a "
NotReadableError
"DOMException
. -
Queue a task to run notify error with e and sensor_instance as arguments.
-
Return.
-
-
Let permission_state be the result of invoking request sensor access with sensor_instance as argument.
-
If permission_state is "granted",
-
Invoke activate a sensor object with sensor_instance as argument.
-
-
Otherwise, if permission_state is "denied",
-
let e be the result of creating a "
NotAllowedError
"DOMException
. -
Queue a task to run notify error with e and sensor_instance as arguments.
-
-
7.1.8. Sensor.stop()
The stop()
method must run these steps:
-
If sensor_instance.
[[state]]
is "idle", then return. -
Set sensor_instance.
[[state]]
to "idle". -
Run these sub-steps in parallel:
-
Invoke deactivate a sensor object with sensor_instance as argument.
-
7.1.9. Sensor.onreading
onreading
is an EventHandler
which is called
to notify that new reading is available.
7.1.10. Sensor.onactivate
onactivate
is an EventHandler
which is called when this.[[state]]
transitions from "activating" to "activated".
7.1.11. Sensor.onerror
onerror
is an EventHandler
which is called whenever
an exception cannot be handled synchronously.
7.1.12. Event handlers
The following are the event handlers (and their corresponding event handler event types)
that must be supported as attributes by the objects implementing the Sensor
interface:
event handler | event handler event type |
---|---|
onreading
| reading
|
onactivate
| activate
|
onerror
| error
|
7.2. The SensorErrorEvent Interface
[SecureContext ,Exposed =(DedicatedWorker ,Window )]interface :
SensorErrorEvent Event {(
constructor DOMString ,
type SensorErrorEventInit );
errorEventInitDict readonly attribute DOMException ; };
error dictionary :
SensorErrorEventInit EventInit {required DOMException ; };
error
7.2.1. SensorErrorEvent.error
Gets the DOMException
object passed to SensorErrorEventInit
.
8. Abstract Operations
8.1. Initialize a sensor object
- input
-
sensor_instance, a
Sensor
object.options, a dictionary object.
- output
-
None
-
For each key → value of options
-
If the associated supported sensor options does not contain key
-
-
If options.
frequency
is present, then-
Set sensor_instance.
[[frequency]]
to options.frequency
.
Note: there is not guarantee that the requested options.
frequency
can be respected. The actual sampling frequency can be calculated usingSensor
timestamp
attributes. -
8.2. Check sensor policy-controlled features
- input
-
sensor_type, a sensor type.
- output
-
True if all of the associated sensor feature names are allowed to use, false otherwise.
-
Let feature_names be the sensor_type’s associated sensor feature names.
-
For each feature_name of feature_names,
-
If active document is not allowed to use the policy-controlled feature named feature_name, then:
-
Return false.
-
-
-
Return true.
8.3. Connect to sensor
- input
-
sensor_instance, a
Sensor
object. - output
-
True if sensor instance was associated with a platform sensor, false otherwise.
-
Let type be the sensor type of sensor_instance.
-
If the device has a single device sensor which can provide readings for type, then
-
Associate sensor_instance with a platform sensor corresponding to this device sensor.
-
Return true.
-
-
If the device has multiple device sensors which can provide readings for type, then
-
If type has an associated default sensor, then
-
Associate sensor_instance with a platform sensor corresponding to default sensor.
-
Return true.
-
-
-
Return false.
8.4. Activate a sensor object
- input
-
sensor_instance, a
Sensor
object. - output
-
None
-
Let sensor be the platform sensor associated with sensor_instance.
-
Append sensor_instance to sensor’s set of activated sensor objects.
-
Invoke set sensor settings with sensor as argument.
-
Queue a task to run notify activated state with sensor_instance as an argument.
8.5. Deactivate a sensor object
- input
-
sensor_instance, a
Sensor
object. - output
-
None
-
Remove all tasks associated with sensor_instance from the task queue associated with sensor task source.
-
Let sensor be the platform sensor associated with sensor_instance.
-
If sensor’s set of activated sensor objects contains sensor_instance,
-
Remove sensor_instance from sensor’s set of activated sensor objects.
-
Invoke set sensor settings with sensor as argument.
-
Set sensor_instance.
[[pendingReadingNotification]]
to false. -
Set sensor_instance.
[[lastEventFiredAt]]
to null.
-
8.6. Revoke sensor permission
- input
-
sensor, a platform sensor.
- output
-
None
-
Let activated_sensors be sensor’s associated set of activated sensor objects.
-
For each s of activated_sensors,
-
Invoke deactivate a sensor object with s as argument.
-
Let e be the result of creating a "
NotAllowedError
"DOMException
. -
Queue a task to run notify error with e and s as arguments.
-
8.7. Set sensor settings
- input
-
sensor, a platform sensor.
- output
-
None
-
If sensor’s set of activated sensor objects is empty,
-
Set requested sampling frequency to null.
-
For each key → value of latest reading.
-
Set latest reading[key] to null.
-
-
Update the user-agent-specific way in which sensor readings are obtained from sensor to no longer provide readings.
-
Return.
-
-
Set requested sampling frequency to optimal sampling frequency.
8.8. Update latest reading
- input
-
sensor, a platform sensor.
reading, a sensor reading.
- output
-
None
-
For each key → value of latest reading.
-
Set latest reading[key] to the corresponding value of reading.
-
-
Let activated_sensors be sensor’s associated set of activated sensor objects.
-
Run these sub-steps in parallel:
-
For each s in activated_sensors,
-
Invoke report latest reading updated with s as an argument.
-
-
8.9. Find the reporting frequency of a sensor object
- input
-
sensor_instance, a
Sensor
object. - output
-
reporting frequency in Hz.
-
Let frequency be null.
-
Let f be sensor_instance.
[[frequency]]
.-
if f is set,
-
set frequency to f capped by the upper and lower sampling frequency bounds for the associated platform sensor.
-
-
Otherwise,
-
user agent can assign frequency to an appropriate value.
-
-
-
return frequency.
8.10. Report latest reading updated
- input
-
sensor_instance, a
Sensor
object. - output
-
None
-
If sensor_instance.
[[pendingReadingNotification]]
is true,-
Return.
-
-
Set sensor_instance.
[[pendingReadingNotification]]
to true. -
Let lastReportedTimestamp be the value of sensor_instance.
[[lastEventFiredAt]]
. -
If lastReportedTimestamp is not set
-
Queue a task to run notify new reading with sensor_instance as an argument.
-
Return.
-
-
Let reportingFrequency be result of invoking Find the reporting frequency of a sensor object.
-
If reportingFrequency is null
-
Queue a task to run notify new reading with sensor_instance as an argument.
-
Return.
-
-
Let reportingInterval be the result of 1 / reportingFrequency.
-
Let timestampDelta be the result of latest reading["timestamp"] - lastReportedTimestamp.
-
If timestampDelta is greater than or equal to reportingInterval
-
Queue a task to run notify new reading with sensor_instance as an argument.
-
Return.
-
-
Let deferUpdateTime be the result of reportingInterval - timestampDelta.
-
Spin the event loop for a period of time equal to deferUpdateTime.
-
If sensor_instance.
[[pendingReadingNotification]]
is true,-
Queue a task to run notify new reading with sensor_instance as an argument.
-
8.11. Notify new reading
- input
-
sensor_instance, a
Sensor
object. - output
-
None
-
Set sensor_instance.
[[pendingReadingNotification]]
to false. -
Set sensor_instance.
[[lastEventFiredAt]]
to latest reading["timestamp"]. -
Fire an event named "reading" at sensor_instance.
8.12. Notify activated state
- input
-
sensor_instance, a
Sensor
object. - output
-
None
-
Set sensor_instance.
[[state]]
to "activated". -
Fire an event named "activate" at sensor_instance.
-
Let sensor be the platform sensor associated with sensor_instance.
-
If sensor’s latest reading["timestamp"] is not null,
-
Queue a task to run notify new reading with sensor_instance as an argument.
-
8.13. Notify error
- input
-
sensor_instance, a
Sensor
object.error, a
DOMException
. - output
-
None
-
Set sensor_instance.
[[state]]
to "idle". -
Fire an event named "error" at sensor_instance using
SensorErrorEvent
with itserror
attribute initialized to error.
8.14. Get value from latest reading
- input
-
sensor_instance, a
Sensor
object.key, a string representing the name of the value.
- output
-
A sensor reading value or null.
-
If sensor_instance.
[[state]]
is "activated",-
Let readings be the latest reading of sensor_instance’s related platform sensor.
-
If the extension specification defines a local coordinate system for sensor_instance,
-
Remap (see [COORDINATES-TRANSFORMATION]) readings values to the local coordinate system.
-
-
Return readings[key].
-
-
Otherwise, return null.
8.15. Request sensor access
- input
-
sensor_instance, a
Sensor
object. - output
-
Let sensor be the platform sensor associated with sensor_instance.
-
Let sensor_permissions be sensor’s associated set of permission names.
-
Run these sub-steps in parallel:
-
For each permission_name in sensor_permissions,
-
Let state be the result of requesting permission to use permission_name.
-
If state is "denied"
-
Return "denied".
-
-
-
Otherwise, return "granted".
-
9. Automation
The Generic Sensor API and its extension specifications pose a challenge to test authors, as fully exercising those interfaces requires physical hardware devices that respond in predictable ways. To address this challenge this document defines a number of extension commands to the [WebDriver] specification for controlling mock sensor on the host that the user agent is running on. With these extension commands, devices with particular properties can be created and their responses to requests are well defined.
9.1. Mock Sensors
A mock sensor simulates the behavior of a platform sensor in controlled ways.
A mock sensor reports a corresponding mock sensor reading, which is a source of
mocking information about the environment, to the Sensor
objects.
The current browsing context's mock sensor has an associated mock sensor reading map.
The mock sensor reading map contains an entry whose key is
"timestamp" and whose value is a high resolution timestamp that estimates the time mock sensor reading sent to observers of the Sensor
object, expressed in milliseconds since the time origin.
The other entries of the mock sensor reading map whose keys must match the dictionary members identifier defined by the mock sensor type's MockSensorReadingValues
and whose initial values are implementation-dependent.
Note: The user agent must provide the mock sensor reading that are initially exposed to the Sensor
objects.
A mock sensor has an associated requested sampling frequency. Its default value is implementation-dependent but must be set within a mock sensor's associated sampling frequency bounds.
A mock sensor has an associated sampling frequency with supported bounds. The default values of supported bounds are implementation-dependent.
A mock sensor must report the mock sensor reading at the rate of its requested sampling frequency if the user agent can expose sensor readings to the current browsing context's active document.
Note: The mock sensor defined in this specification is not intended be used by non-testing-related web content. The UA MAY choose to expose mock sensor interface only when a runtime or compile-time flag has been set.
9.1.1. MockSensorConfiguration dictionary
dictionary {
MockSensorConfiguration required MockSensorType ;
mockSensorType boolean =
connected true ;double ?;
maxSamplingFrequency double ?; };
minSamplingFrequency
The MockSensorConfiguration
dictionary is used to create a mock sensor.
mockSensorType
member-
A
MockSensorType
that is used to set mock sensor type. connected
member-
A boolean that indicates a mock sensor's connection flag which is used for switching the connection between
Sensor
object and mock sensor. When set to false the user agent must force the result of invoking connect to sensor with mock sensor's associatedSensor
object as argument to false, otherwise true. maxSamplingFrequency
member-
A double representing frequency in Hz that is used to set maximum supported sampling frequency for the associated mock sensor.
minSamplingFrequency
member-
A double representing frequency in Hz that is used to set minimum supported sampling frequency for the associated mock sensor.
9.1.2. MockSensor dictionary
dictionary {
MockSensor double ;
maxSamplingFrequency double ;
minSamplingFrequency double ; };
requestedSamplingFrequency
The MockSensor
dictionary provides information about a mock sensor.
maxSamplingFrequency
member-
A double representing frequency in Hz that indicates the maximum supported sampling frequency of the associated mock sensor.
minSamplingFrequency
member-
A double representing frequency in Hz that indicates the minimum supported sampling frequency of the associated mock sensor.
requestedSamplingFrequency
member-
A double representing frequency in Hz that indicates the requested sampling frequency of the associated mock sensor.
A serialized mock sensor is a JSON Object where a mock sensor's fields listed in the MockSensor
dictionary are mapped
using the JSON Key and the associated field’s value from the available mock sensor in current browsing context.
9.1.3. Mock sensor type
A mock sensor type is equivalent to a sensor type's associated Sensor
subclass.
enum {
MockSensorType "ambient-light" ,"accelerometer" ,"linear-acceleration" ,"gravity" ,"gyroscope" ,"magnetometer" ,"uncalibrated-magnetometer" ,"absolute-orientation" ,"relative-orientation" ,"geolocation" ,"proximity" , };
Each enumeration value in the MockSensorType
enum identifies a mock sensor type.
"ambient-light"
-
A mock sensor type associated with the usage of the AmbientLightSensor interface.
"accelerometer"
-
A mock sensor type associated with the usage of the Accelerometer interface.
"linear-acceleration"
-
A mock sensor type associated with the usage of the LinearAccelerationSensor interface.
"gravity"
-
A mock sensor type associated with the usage of the GravitySensor interface.
"gyroscope"
-
A mock sensor type associated with the usage of the Gyroscope interface.
"magnetometer"
-
A mock sensor type associated with the usage of the Magnetometer interface.
"uncalibrated-magnetometer"
-
A mock sensor type associated with the usage of the UncalibratedMagnetometer interface.
"absolute-orientation"
-
A mock sensor type associated with the usage of the AbsoluteOrientationSensor interface.
"relative-orientation"
-
A mock sensor type associated with the usage of the RelativeOrientationSensor interface.
"geolocation"
-
A mock sensor type associated with the usage of the GeolocationSensor interface.
"proximity"
-
A mock sensor type associated with the usage of the ProximitySensor interface.
Each mock sensor type has a mock sensor reading values dictionary:
- Mock Sensor Reading Values dictionary
-
MockSensorReadingValues
dictionary represents a user-specified mock sensor reading used for updating a mock sensor reading. Its members must match the attribute identifier defined by the sensor type's associated extension sensor interface. Each mock sensor type has a specificMockSensorReadingValues
, which is defined in each extension specifications.dictionary
{ };MockSensorReadingValues
9.2. Extension Commands
9.2.1. Create mock sensor
HTTP Method | URI Template |
---|---|
POST | /session/{session id}/sensor |
The create mock sensor extension command creates a new mock sensor.
The remote end steps are:
-
Let configuration be the configuration parameter, converted to an IDL value of type
MockSensorConfiguration
. If this throws an exception, return a WebDriver error with WebDriver error code invalid argument. -
Let type be the configuration.
mockSensorType
. If the current browsing context already has this type of mock sensor, return a WebDriver error with WebDriver error code mock sensor already created. -
If the current browsing context is no longer open, return a WebDriver error with WebDriver error code no such window.
-
Handle any user prompts, and return its value if it is a WebDriver error.
-
Run these sub-steps in parallel to create a mock sensor in the current browsing context:
-
Let mock be a new mock sensor.
-
Set mock’s mock sensor type to type.
-
Let connected be the configuration.
connected
, set mock’s associated connection flag to connected. -
If configuration.
maxSamplingFrequency
is present, then:-
Set mock’s maximum supported sampling frequency to configuration.
maxSamplingFrequency
.
-
-
If configuration.
minSamplingFrequency
is present, then:-
Set mock’s minimum supported sampling frequency to configuration.
minSamplingFrequency
.
-
-
Let sensor_instance be a type of
Sensor
object, set sensor_instance’s associated platform sensor to mock.
-
-
Return success with data
null
.
/session/23/sensor
with the body:
{ "mockSensorType" : "ambient-light" , "maxSamplingFrequency" : 60 , "minSamplingFrequency" : 5 }
Be aware that only one mock sensor of a given mock sensor type can be created in current browsing context, otherwise a WebDriver error with WebDriver error code mock sensor already created will be thrown.
9.2.2. Get mock sensor
HTTP Method | URI Template |
---|---|
GET | /session/{session id}/sensor/{type} |
The get mock sensor extension command retrieves information about a given type of mock sensor.
The remote end steps are:
-
Let type be a url variable, converted to an IDL value of type
MockSensorType
. If this throws an exception, return a WebDriver error with WebDriver error code invalid argument. -
If the current browsing context is no longer open, return a WebDriver error with WebDriver error code no such window.
-
Handle any user prompts, and return its value if it is a WebDriver error.
-
If type does not match a mock sensor type amongst all associated mock sensors of the current browsing context, return a WebDriver error with WebDriver error code no such mock sensor.
-
Return success with the serialized mock sensor as data.
9.2.3. Update mock sensor reading
HTTP Method | URI Template |
---|---|
POST | /session/{session id}/sensor/{type} |
The update mock sensor reading extension command updates a given type of mock sensor's reading.
The remote end steps are:
-
Let type be a url variable, converted to an IDL value of type
MockSensorType
. If this throws an exception, return a WebDriver error with WebDriver error code invalid argument. -
If the current browsing context is no longer open, return a WebDriver error with WebDriver error code no such window.
-
Handle any user prompts, and return its value if it is a WebDriver error.
-
If type does not match a mock sensor type amongst all associated mock sensors of the current browsing context, return a WebDriver error with WebDriver error code no such mock sensor.
-
Let reading be the reading argument, converted to an IDL value of the type’s associated
MockSensorReadingValues
. If this throws an exception, return a WebDriver error with WebDriver error code invalid argument. -
For each key → value of reading.
-
Set mock sensor reading[key] to the corresponding value of reading.
-
-
Return success with data
null
.
9.2.4. Delete mock sensor
HTTP Method | URI Template |
---|---|
DELETE | /session/{session id}/sensor/{type} |
The delete mock sensor extension command deletes a given type of mock sensor.
The remote end steps are:
-
Let type be a url variable.
-
If
MockSensorType
does not contain type, return a WebDriver error with WebDriver error code invalid argument. -
If the current browsing context is no longer open, return a WebDriver error with WebDriver error code no such window.
-
Handle any user prompts, and return its value if it is a WebDriver error.
-
If type does not match a mock sensor type amongst all associated mock sensors of the current browsing context, return a WebDriver error with WebDriver error code no such mock sensor.
-
Delete type of mock sensor in current browsing context.
-
Return success with data
null
.
9.3. Handling errors
This section extends the Handling Errors and defines extended WebDriver error codes specific for mock sensor in following table.
Error Code | HTTP Status | JSON Error Code | Description |
---|---|---|---|
no such mock sensor | 404 | no such mock sensor
| no mock sensor matching the given type was found. |
mock sensor already created | 500 | mock sensor already created
| A command to create a mock sensor could not be satisfied because the given type of mock sensor is already existed. |
10. Extensibility
This section is non-normative.
Note: This section and its subsections provide guidance to extension specification authors using normative language. From implementers' point of view, this section and its subsections are considered non-normative.
This section describes how this specification can be extended to specify APIs for different sensor types.
Such extension specifications are encouraged to focus on a single sensor type, exposing both high and low level as appropriate.
Extension specifications are encouraged to define whether a calibration process applies to sensor readings.
Extension specifications may explicitly define the local coordinate system for the associated sensor type or make it configurable per Sensor
object.
For an up-to-date list of extension specifications, please refer to [GENERIC-SENSOR-USECASES] and [MOTION-SENSORS] documents.
10.1. Security and Privacy
Extension specifications are expected to:
-
conform with the generic mitigation strategies,
-
consider mitigation strategies applied on a case by case basis,
-
be evaluated against the Self-Review Questionnaire on Security and Privacy [SECURITY-PRIVACY-QUESTIONNAIRE],
-
and in particular, be evaluated against the same-origin policy violations that can arise if sensors expose a new communication channel not governed by the same-origin policy.
10.2. Naming
Sensor
interfaces for low-level sensors should be
named after their associated platform sensor.
So for example, the interface associated with a gyroscope
should be simply named Gyroscope
. Sensor
interfaces for high-level sensors should be
named by combining the physical quantity the platform sensor measures
with the "Sensor" suffix.
For example, a platform sensor measuring
the distance at which an object is from it
may see its associated interface called ProximitySensor
.
Attributes of the Sensor
subclass that
hold sensor readings values
should be named after the full name of these values.
For example, the Thermometer
interface should hold
the sensor reading's value in
a temperature
attribute (and not a value
or temp
attribute).
A good starting point for naming are the
Quantities, Units, Dimensions and Data Types Ontologies [QUDT].
10.3. Unit
Extension specifications must specify the unit of sensor readings.
As per the Technical Architecture Group’s (TAG) API Design Principles [API-DESIGN-PRINCIPLES], all time measurement should be in milliseconds. All other units should be specified using, in order of preference, and with the exception of temperature (for which Celsius should be favored over Kelvin), the International System of Units (SI), SI derived units, and Non-SI units accepted for use with the SI, as described in the SI Brochure [SI].
10.4. Exposing High-Level vs. Low-Level Sensors
So far, specifications exposing sensors to the Web platform have focused on high-level sensors APIs. [GEOLOCATION-API] [ORIENTATION-EVENT]
This was a reasonable approach for a number of reasons. Indeed, high-level sensors:
-
convey developer intent clearly,
-
do not require intimate knowledge of how the underlying hardware sensors functions,
-
are easy to use,
-
may enable the User Agent to make significant performance and battery life improvements,
-
help avoid certain privacy and security issues by decreasing the amount and type of information exposed.
However, an increasing number of use cases such as virtual and augmented reality require low-level access to sensors, most notably for performance reasons.
Providing low-level access enables Web application developers to leverage domain-specific constraints and design more performant systems.
Following the precepts of the Extensible Web Manifesto [EXTENNNNSIBLE], extension specifications should focus primarily on exposing low-level sensor APIs, but should also expose high-level APIs when they are clear benefits in doing so.
10.5. When is Enabling Multiple Sensors of the Same Type Not the Right Choice?
It is not advisable to construct multiple Sensor
instances of the same sensor type with
equal construction parameters, as it can lead to unnecessary hardware resources consumption.
In cases when multiple observers are interested in notifications of a newly available sensor reading, an event listener can be added on a single Sensor
instance instead of
creating multiple instances of the same sensor type and using simple onreading
event
handler.
Conversely, multiple Sensors
of the same sensor type can be created when they
are intended to be used with different settings, such as: requested sampling frequency,
accuracy or other settings defined in extension specifications.
10.6. Definition Requirements
The following definitions must be specified for each sensor type in extension specifications:
-
An extension sensor interface, which is an interface whose inherited interfaces contains
Sensor
. The extension sensor interface must be constructible. Its [Constructor
] must take, as an argument, an optional dictionary whose inherited dictionaries containsSensorOptions
.The extension sensor interface has a set of supported options referred to as supported sensor options. Unless the extension specification defines otherwise, supported sensor options contain a single item which is "frequency".
The user agent must remove items from supported sensor options for a given extension sensor interface if it cannot support the corresponding sensor options.
The extension sensor interface attributes which expose sensor readings are read only and their getters must return the result of invoking get value from latest reading with this and attribute identifier as arguments.
-
A permission name, if the sensor type is not representing sensor fusion (otherwise, permission names associated with the fusion source sensor types must be used).
An extension specification may specify the following definitions for each sensor types:
-
A dictionary whose inherited dictionaries contains
SensorOptions
. -
A default sensor. Generally, devices are equipped with a single platform sensor of each type, so defining a default sensor should be straightforward. For sensor types where multiple sensors are common, extension specifications may choose not to define a default sensor, especially when doing so would not make sense.
10.7. Automation
In order to enable user-agent automation and application testing, extension specifications are encouraged to:
-
Add new mock sensor type for each extension sensor interface to the
MockSensorType
enum. -
Define a mock sensor reading values dictionary.
10.8. Extending the Permission API
An implementation of the Sensor
interface for each sensor type must protect its reading by associated permission name or PermissionDescriptor
.
A Low-level sensor
may use its interface name as a permission name,
for instance, "gyroscope" or "accelerometer". Fusion sensors must request permission to access each of the sensors that are
used as a source of fusion.
Even though it might be difficult to reconstruct low-level sensor readings from fused data, some of the original information might be inferred. For example, it is easy to deduce user’s orientation in space if absolute or geomagnetic orientation sensors are used, therefore, these sensors must request permission to use magnetometer as it provides information about orientation of device in relation to Earth’s magnetic field. In contrast, relative orientation sensor does not expose such information, thus, it does not need to request permission to use magnetometer.
Permission descriptors
can also be used to set maximum allowed limits
for accuracy or sampling frequency. An example for a possible extension of the Permission API
for accelerometer sensor is given below.
dictionary AccelerometerPermissionDescriptor : PermissionDescriptor { boolean highAccuracy = false; boolean highFrequency = false; };
10.9. Extending the Feature Policy API
An implementation of the Sensor
interface for each sensor type has one
(if sensor fusion is not performed) or several policy-controlled features that control whether or not this implementation can be used in a document.
The features' default allowlist is ["self"]
.
Note: The default allowlist of ["self"]
allows Sensor
interface
implementation usage in same-origin nested frames but prevents third-party content
from sensor readings access.
The sensor feature names set must contain policy-controlled feature tokens of every associated feature.
A Low-level sensor
may use its interface name as a policy-controlled feature token,
for instance, "gyroscope" or "accelerometer". Unless the extension specification defines
otherwise, the sensor feature names matches the same type-associated sensor permission names.
< iframe src = "https://third-party.com" allow = "accelerometer" /></ iframe >
Feature- Policy: accelerometer'none'
Fusion sensors must use sensor feature names of the sensors that are used as a source of fusion.
< iframe src = "https://third-party.com" allow = "accelerometer; magnetometer; gyroscope" />
10.10. Example WebIDL
Here’s an example WebIDL for a possible extension of this specification for proximity sensors.
[SecureContext, Exposed=Window] interface ProximitySensor : Sensor { constructor(optional ProximitySensorOptions proximitySensorOptions = {}); readonly attribute double? distance; }; dictionary ProximitySensorOptions : SensorOptions { double min; double max; ProximitySensorPosition position; ProximitySensorDirection direction; }; enum ProximitySensorPosition { "top-left", "top", "top-right", "middle-left", "middle", "middle-right", "bottom-left", "bottom", "bottom-right" }; enum ProximitySensorDirection { "front", "rear", "left", "right", "top", "bottom" };
11. Acknowledgements
First and foremost, I would like to thank Anssi Kostiainen for his continuous and dedicated support and input throughout the development of this specification, as well as Mikhail Pozdnyakov, Alexander Shalamov, Rijubrata Bhaumik, and Kenneth Rohde Christiansen for their invaluable implementation feedback, suggestions, and research that have helped inform the specification work.
Special thanks to Rick Waldron for driving the discussion around a generic sensor API design for the Web, sketching the original API on which this is based, providing implementation feedback from his work on Johnny-Five, and continuous input during the development of this specification.
Special thanks to Boris Smus, Tim Volodine, and Rich Tibbett for their initial work on exposing sensors to the web with consistency.
Thanks to Anne van Kesteren for his tireless help both in person and through IRC.
Thanks to Domenic Denicola and Jake Archibald for their help.
Thanks also to Frederick Hirsch and Dominique Hazaël-Massieux (via the HTML5Apps project) for both their administrative help and technical input.
Thanks to Tab Atkins for making Bikeshed and taking the time to explain its subtleties.
Thanks to Lukasz Olejnik and Maryam Mehrnezhad for their contributions around privacy and security.
The following people have greatly contributed to this specification through extensive discussions on GitHub: Anssi Kostiainen, Boris Smus, chaals, Claes Nilsson, Dave Raggett, David Mark Clements, Domenic Denicola, Dominique Hazaël-Massieux (via the HTML5Apps project), Francesco Iovine, Frederick Hirsch, gmandyam, Jafar Husain, Johannes Hund, Kris Kowal, Lukasz Olejnik, Marcos Caceres, Marijn Kruisselbrink, Mark Foltz, Mats Wichmann, Matthew Podwysocki, Olli Pettay, pablochacin, Remy Sharp, Rich Tibbett, Rick Waldron, Rijubrata Bhaumik, robman, Sean T. McBeth, Tab Atkins Jr., Virginie Galindo, zenparsing, and Zoltan Kis.
We’d also like to thank Anssi Kostiainen, Dominique Hazaël-Massieux, Erik Wilde, and Michael[tm] Smith for their editorial input.
Conformance
Document conventions
Conformance requirements are expressed with a combination of descriptive assertions and RFC 2119 terminology. The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in the normative parts of this document are to be interpreted as described in RFC 2119. However, for readability, these words do not appear in all uppercase letters in this specification.
All of the text of this specification is normative except sections explicitly marked as non-normative, examples, and notes. [RFC2119]
Examples in this specification are introduced with the words "for example"
or are set apart from the normative text with class="example"
,
like this:
Because this document doesn’t itself define APIs for specific sensor types—
Informative notes begin with the word "Note" and are set apart from the
normative text with class="note"
, like this:
Note, this is an informative note.
Conformant Algorithms
Requirements phrased in the imperative as part of algorithms (such as "strip any leading space characters" or "return false") are to be interpreted with the meaning of the key word ("must", "should", "may", etc) used in introducing the algorithm.
Conformance requirements phrased as algorithms or specific steps can be implemented in any manner, so long as the end result is equivalent. In particular, the algorithms defined in this specification are intended to be easy to understand and are not intended to be performant. Implementers are encouraged to optimize.
Conformance Classes
A conformant user agent must implement all the requirements listed in this specification that are applicable to user agents.